VMX-1020 CO2 INSUFFLATOR
short description here Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor
Key points of the machine:
VIMAP |
OTHERS |
|
---|---|---|
YES |
NO | Heating system heating the CO2 up to 38,5°c in order to Relax the colon muscles |
YES |
NO | Possibility to adapt the insufflation to the patient preparation level of cleanliness |
YES |
NO | 3-way catheters for better drainage of liquids during insufflation |
YES |
NO | Buscopan not required due to exceptional heating system |
YES |
NO | Intussusception mode + specific intussusception reduction administration set reference |
YES |
NO | Large touch monitor for easy reading from the CT control room |
YES |
NO | Optimal height of the touch screen for standing up operation and to be higher than CT table and patient |
YES |
NO | Small foot print (XXcm of diameter) for easy storage |
YES |
NO | Using large CO2 cylinders of 3-4l of chargeSpecific cart for safe storage of 2 large cylinders and administration sets |
YES |
NO | Double filtration with 2 hydrophilic filters protecting patient and machine with the highest viral and bacterial characteristics |
patented*
And more…
- Fine and high precision regulation with 1mmHg of precision
- Over pressure free due to sophisticated electronic and proportional regulation of overpressures
- Easy and free software updates to newest versions
- Easy preventive maintenance on site due to a maintenance tool box connected to the device
- Friendly interface and easy to use
UNMATCHED SAFETY FEATURES
Multiple mechanical safety valve
- Limiter at 3,8 bar (55 PSI) and 0,26 bars (4 PSI) entrance pressure in the insufflator
- Pressure release at 155 mmHg (3 PSI) and 77 mmHg (1,5 PSI) operating without power
- Safety electrovalves for virtual colonoscopy and and for optical colonoscopy and intussusception
Safe pressure management
- Constant pressure and constant temperature of the CO2
- The system offers fast, instantaneous and progressive release of over pressure through a proportional electronic valveand a second high release valve for high overpressure (contractions or change of position of the patient)

Safety Features
Lorem ipsum dolor sit amet, consectetur adipiscing elit, sed do eiusmod tempor incididunt ut labore et dolore magna aliqua. Ut enim ad minim veniam, quis nostrud exercitation ullamco laboris nisi ut aliquip ex ea commodo co
Can Adapt the insufflation to the patient preparation level of cleanelyness
Sensor Monitoring
For added safety, the VMX-1020A has a built in multiple pressure sensors with constant electronic monitoring, which

HEATING SYSTEM
PATENTED
LESS PRESSURE NEEDED, SAFER OPERATION
Our advanced heating system can heat the CO2 up to 38,5°C in order to relax the colon muscles.
According to clinical trials, heating the colon relaxes the muscles and helps the distension. The consequence is that you need can set less pressure for the same distention. Setting less pressure is safer and more comfortable for the patient.
BUSCOPAN NO LONGER REQUIRED
With the heating system of the VMX-1020A, you will no longer need Buscopan injection.
Getting ride of Buscopan injection is a key safety feature for patients, as it has a long list of side effects that can be very severe. It also allows the patient to drive his car home immediately after the exam, which is not recommended after a Buscopan injection.


OVERPRESSURE FREE
Over pressure free due to sophisticated electronic and proportional regulation of overpressures..
Overpressures often generate spasms and the consequence is that segments of the colon are contracting. You have irregular distension and some collapsed segments that will be very difficult to analyze during the diagnostic. VMX-1020A has a proportional real-time multi-valves system to prevent over pressures and to prevent spasms.
INTUSSUSCEPTION REDUCTION MODE
EXCLUSIVE
NEEDS DESCRIPTION
NEEDS DESCRIPTION.
Currently the only machine in the world capable of (text needed)
INTUSSUSCEPTION REDUCTION ADMINISTRATION SET
needs description


USES LARGE C02 TANKS
The specially made cart can fit 2 tanks of up to 4L each, allowing
CONTACT FORM
EXAMPLE OF PROCEDURES
- peripheral extremity arteries
- aortography Runoff
- renal artery angioplasty and stenting
- visceral angiography intervention
- transplant renal artery DSA for detection of bleeding
mesenteric artery - abdominal aortogram
- femoral arteries
- popliteal arteries
- guided EVARCO2Iliac or pelvic artery
- peripheral and central vein
- upper extremity venography for hemodialysis access
- splenoportal venogram
- arm venogram
- vena cavography prior to filter placement
- inferior vena cava
- renal Vein
- direct Portography
- wedged hepatic venography
- splenoportography
- lower Limb
- dialysis Fistula
- pelvic Anteriogram
- leg Anteriogram
- renal Transplant
- TIPS procedure